FTCGS-1 Flight Termination Control

The Flight Termination Control Ground System Series FTCGS-1 is a fully integrated, dual redundant flight termination control system comprising of a 19” Main Unit with two external transmission modules. Distance between the shelter based Main Unit and the external Transmission Modules, which are to be mounted at the antenna mast, can be up to 50 meters. The design is made with respect to the stringent reliability demands of today’s test ranges.

 

The FTCGS-1 is designed to meet the RCC319/92 standard. There are several options available to meet specific frequency, tone sequence, programming, output power and remote control requirements.

Technical Specification


Frequency Range 380 to 470 MHz
Frequency Selection by software in 10 kHz steps
Frequency Stability ≤ ± 0,005%
Output Power 1 to 20 Watts, min.
Output Impedance 50 Ohm
VSWR better than 1,5 :1
Spurious Radiation ≤ -70 dBc
Harmonics ≤ -60 dBc
Type true FM
Deviation ±30 KHz/Tone, programmable
Sense positive
Tones up to 4 (ch #1 to #10)
Power Supply 85 to 265 VAC 47-63 Hz
RF Connector N female
Dimensions Main : 19 » / 3HE TM : 260 x 160 x 120 mm
Temperature Range Main: +5C to +40C
operational TM: -25C to +60C
Storage -40C to + 85C